平成  年  月  日 月曜日 官 報 (号外政府調達第  号) } The whole system should implement high‐level network security measures for both protecting the systems from external attacks and internal network management of connection, monitoring, and user restrictions. 〜 The system should have high reliability in both hardware and software. Quick support and maintenance should also be available.  Operation of this system should be automated and utmost labor saving effort should be done : and automatic operation in the long haul should be facilitated. ‘ Outline of Total Evaluation : The successful bid depends on total evaluations of the price, the performance and the function, etc. The introduction manual shows the outline of the total evaluation. a Time‐limit for the submission of the requested material : 5 : 00 PM 26, March, 2012. b Contact point for the notice : Naho Takatsu, Accounting Section, General Affairs Division, Incorporated Administrative Agency, National Institute for Environmental Studies, 16‘2 Onogawa Tsukubashi Ibaraki‐ken 305‘8506 Japan. TEL 029‘850‘2321 資料提供招請に関する公表 次のとおり物品の導入を予定していますので、 当該導入に関して資料等の提供を招請します。 平成 24 年2月 13 日 国立大学法人筑波大学 附属病院長 五十嵐徹也 ◎調達機関番号 415 ◎所在地番号 08 〇第5号 1 調達内容 ¥ 品目分類番号 22、31 ] 導入計画物品及び数量 可動式術中MRI システム 一式 ^ 調達方法 借入 _ 導入予定時期 平成24年度11月以降 ‘ 調達に必要とされる基本的な要求要件 A MRIの磁場強度による種類 中磁場 (1 5テスラ)装置であること。 B 手術室とMRI検査室を隣接し、MRI 装置が移動すること。 C 術中MRIに付帯する設備 a ナビゲーション(天吊り型) MRI で撮影した脳の機能情報(言語・運動領 域の場所)を手術で利用する。顕微鏡と ナビゲーションをリンクする機能および それに伴う装置・ソフトウエアを備えて いる必要がある。 b MRI対応手術ベッド・頭部固定フ レーム 頭部をフレーム固定した状態で MRIが患者のところまで移動し、撮像 する。 c 天吊りシステム ナビゲーション用カ メラとモニター、電源、医療ガス、 吸引、 無影灯(術野カメラ付を含む) 、患者情 報モニター(術野カメラ映像、顕微鏡映 像、生理学的モニタ画面、内視鏡画面、 生体情報、病院ネットワークとの接続も 含む) 、など)を天吊りにする。 d 手術室レイアウト・MRI室と手術室 の連動 ドアのセーフティロック機構の 設置 D MRI用コイル (頭部、脊椎、体幹、 乳房、関節、心臓) E スペクトロスコピー(LC model 等の 解析ソフトを含む) 、DTI、 functional MRI、MR perfusionの解析機能を備え ていること。 F 高速の画像処理及び機能解析ができるた めのwork stationを備えていること。 G データの保管及び配信ができること。 H 当院のHIS、RISおよびPACSと 接続し情報の保存および送受信ができるこ と。また、その情報が手術室内の天吊りモ ニターとも接続されていること。 2 資料及びコメントの提供方法 上記1]の物 品に関する一般的な参考資料及び同‘の要求要 件等に関するコメント並びに提供可能なライブ ラリーに関する資料等の提供を招請する。 ¥ 資料等の提供期限 平成24年3月30日17時 00分(郵送の場合は必着のこと。 ) ] 提供先 〒305‘8576 つくば市天久保2丁 目1番地の1 国立大学法人筑波大学病院総 務部管理課契約第一 澤邊 昇 電話 029‘853‘3515 3 説明書の交付 本公表に基づき応募する供給 者に対して導入説明書を交付する。 ¥ 交付期間 平成24年2月13日から平成24年 3月30日まで。 ] 交付場所 上記2]に同じ。 4 説明会の開催 本公表に基づく導入説明会を 開催する。 ¥ 開催日時 平成24年2月22日14時00分 ] 開催場所 国立大学法人筑波大学附属病院 A棟3階共通会議室 5 その他 この導入計画の詳細は導入説明書に よる。なお、本公表内容は予定であり、変更す ることがあり得る。 6 Summary ¥ Classification of the products to be procured : 22, 31 ] Nature and quantity of the products to be rent : Mobile intraoperative MR imaging system 1 Set ^ Type of the procurement : Rent _ Basic requirements of the procurement : A Field strength of the magnet : The MRI system should be with a superconducting magnet of moderate field (1.5 T) strength. B The operating room should be next to the diagnostic room : moreover, the magnet should be moved from the diagnostic room to the operating room. C This system must have the following requirements. a Neuronavigation (ceiling‐mounted type) : functional imaging data derived with diffusion tensor imaging (DTI) and functional MRI can be used for navigation (functional navigation). In addition, these data should be visualized in the surgical field by microscope (microscope‐based navigation). b MR‐compatible operating room table and head clump : the magnet should be moved to operative field, and then scanning is performed. c Ceiling pendant : following apparatuses should be ceiling‐mounted : camera and monitor of neuronavigation, power supply, in/outlet of medical and anesthetic gas, suction outlet, light, displays and patient monitor connected with surgical field camera, microscope, physiological monitoring, endoscope, and hospital PACS. d Total layout of operating room : integration of operating and diagnostic room : central control of locking doors D Coils for MR imaging E This system can perform MR spectroscopy, DTI, functional MRI, MR perfusion and its analysis. This system should include softwares for the analysis (e. g. LC model for MR spectroscopy) F This system should include a workstation that is capable of fast image processing and functional analysis. G This system can store and send the images. H This system should be connected with HIS, RIS and PACS of the hospital and their information can be transferred each other. ‘ Time limit for the submission of the requested material : 5 : 00 PM 30, March, 2012 a Contact point for the notice : Noboru Sawabe, First Section of Contract, Division of Finance, Department of University Hospital Management, University of Tsukuba, 2‘1‘1 Amakubo Tsukuba‐shi 305‘8576 Japan, TEL 029‘853‘3515 資料提供招請に関する公表 次のとおり物品の導入を予定していますので、 当該導入に関して資料等の提供を招請します。 平成 24 年2月 13 日 国立大学法人浜松医科大学 理事 瀧川 雅浩 ◎調達機関番号 415 ◎所在地番号 22 〇第5号 1 調達内容 ¥ 品目分類番号 22、31 ] 導入計画物品及び数量 マルチスライスC T装置 一式