(号外政府調達第  号) 報 官 木曜日 平成  年  月  日 The system must have an integrated function that record the special report from endoscopy, ultrasonography, ophthalmologic test, and dermatologic photograph. D The system must have a function to record the visual examination data that relate to the medical information system, which is put in our hospital present and after time. E The system must have a function to record the visual examination data under the general format for freeze‐flame and motion picture regardless of clinical department. F The system must have a function supporting to write a medical record, especially for the clinical departments that have many examinations in themselves. G The system must have a function to add, alter and tinker with the recoded picture. This function should be mounted for the informed consent. H The system must formulate thoroughgoing safety and security measures supporting our intervention. I The system must be build up with server and client formation and must have a function that refer easily to the data recorded in the sever for information about the picture record through the client of our medical information system. J The system must be designed and produced to support the clinical work and must be introduced after the sufficient tests. K The system must be non‐stop system and must keep a sufficient response. L The administration function of the system must be designed with the security and the labor saving. M The vender of the system must have framework of repairing and maintenance the system and must have the operation training team. C | デジタル画像データを利用した3D解 The vender of the system must disclosure the components of the databases. 析、その他計測等ができる機能を有する。 O The vender of the system must make } デジタルX線映画撮影用のネットワーク the accumulated data on existing medical を敷設し、複数箇所の画像再生装置で画像 information system convert to the re観察、画像解析等の機能が同時に行えるシ quired system under our assignment. In ステムである。 that regard, the vender of the system 〜 画像および患者情報の送受信ができる。 must supply the technical information to 2 資料及びコメントの提供方法 上記1]の物 use the data on the required system. 品に関する一般的な参考資料及び同‘の要求要 P The vender of the system must supply 件等に関するコメント並びに資料等の提供を招 the technical information when we will 請します。 try to convert the data from required sys¥ 資料等の提出期限 平成22年10月12日14時 tem to another one in the future. And the 00分(現地時間) vender of the system must authorize us (郵送の場合は必着のこと) and outsiders to use your technical infor] 提出先 〒141‘8625 東京都品川区東五反 mation when we try to convert the data. ‘ Time limit for the submission of the re田5‘9‘22 東日本電信電話株式会社関東 quested material : 5 : 00 PM 27, September, 病院 企画担当 冨宇加 進 2010 電 話(03)3448‘6126 a Contact point for the notice : Mayumi ファックス(03)3448‘6127 Idobata, Contract Team, Finance Departmなお、NTT東日本ホームページ ent, Mie University, 1577 Kurimamatiyahttp://www.ntt‐east.co.jp/purchase/ cho Tsu‐shi 514‘8507 Japan, TEL 059‘ inquiry/index.html 記載窓口においても問 231‘5320 い合わせを行います。 資料提供招請に関する公表 3 Summary ¥ Classification of the products to be Pro東日本電信電話株式会社公告第9号 cured : 22, 31 次のとおり物品の導入を予定していますので、 ] Name and quantity of the products to be 当該導入に関して資料等の提供を招請します。 Purchased : Cardiovascular Diagnostic Xなお、本招請は資料等提供者の機密情報及び財 ray System 1set 産的情報の提出を求めるものではありません。 ^ Type of the procurement : purchase 平成 22 年8月 26 日 東日本電信電話株式会社 _ Introductory schedule time : March, 2011 関東病院長 落合 慈之 ‘ Basic requirements of the procurement : ◎調達機関番号 125 ◎所在地番号 13 { To perform diagnostic imaging and 〇関病企第 10‘276 号 IVR of the cardiaovascular system. 1 調達内容 The system must be a biplane system in¥ 品目分類番号 22、31 corporates a flat panel detector which is ] 導入計画物品名称及び数量 循環器X線診 capable of multidirectional fluoroscopy 断装置 一式 and digital X‐ray cine imaging. ^ 調達方法 購入等 | The system must retain the ability to _ 導入予定時期 平成23年3月 3D analysis and other measurements. ‘ 調達に必要とされる基本的な要求用件 } The system must be equipped with a { 循環器系画像診断およびIVR施行のた network dedicated to digital X‐ray cine め、フラットパネルディテクタを搭載した imaging and must allow simultaneous imバイプレーンシステムによる多方向からの age display and analysis on more image 透視およびデジタルX線映画撮影ができる 装置である。 review system. N 〜 The system must be able to send and receive images and patient information. a Time‐limit for the submission of the Requested material : 2 : 00 PM Oct 10, 2010 (Local Time) b Contact point for the notice : a.KANTO MEDICAL CENTER NTT EC 5‘9‘22 Higashi‐gotanda Shinagawa‐ku, Tokyo Japan TEL : 81^3448‘6126 FAX : 81^3448‘6127 Attn. : Susumu Tomiuka b.Overseas contact points described on the following URL. http://www.ntt‐east.co.jp/purchase/ inquiry/index.html 資料提供招請に関する公表 東日本電信電話株式会社公告第10号 次のとおり物品の導入を予定していますので、 当該導入に関して資料等の提供を招請します。 なお、本招請は資料等提供者の機密情報及び財 産的情報の提出を求めるものではありません。 平成 22 年8月 26 日 東日本電信電話株式会社 関東病院長 落合 慈之 ◎調達機関番号 125 ◎所在地番号 13 〇関病企第 10‘276 号 1 調達内容 ¥ 品目分類番号 22、31 ] 導入計画物品名称及び数量 注射薬自動取 り揃えシステム 一式 ^ 調達方法 購入等 _ 導入予定時期 平成23年3月 ‘ 調達に必要とされる基本的な要求用件 { 電子カルテシステムと連動する注射薬処 方のオーダリングシステムから注射薬の データがとれること | 自動注射薬取り揃えシステムから注射処 方せん、 輸液ラベルの印字、 さらにバーコー ド等の印刷ができること } バーコード等の印刷は2次元バーコー ド、2次元シンボル等で印字できること