17-Jun-2003 17:16:53 :%DELL-I-STATUS: The product global status has changed from non-critical to critical
at time -1966726688.
17-Jun-2003 17:16:53 :%Box-A-FAN-STAT-CHNG: FAN# 1 status changed - not operational.
17-Jun-2003 17:16:48 :%DELL-I-STATUS: The product global status has changed from critical to non-critical
at time -1966727188.
17-Jun-2003 17:16:48 :%Box-I-FAN-STAT-CHNG: FAN# 1 status changed - operational.
PC5324> show system
System Description: Ethernet Switch
System Up Time (days,hour:min:sec): 1273,07:11:22
FAN Status
------------- ------
1 NOT OPERATIONAL
2 OK
まじめに寿命ですかね.... 投入してもう5年ぐらいかな。一度UPS交換で電源落としたぐらい。
# smartctl -a /dev/ad4
=== START OF INFORMATION SECTION ===
Device Model: FB080C4080
Serial Number: XXXXX
Firmware Version: XXXXX
User Capacity: 80,026,361,856 bytes
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0
3 Spin_Up_Time 0x0002 098 097 000 Old_age Always - 0
4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 50
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 611848220
9 Power_On_Hours 0x0032 049 049 000 Old_age Always - 45439
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 51
184 End-to-End_Error 0x0032 100 253 000 Old_age Always - 0
187 Reported_Uncorrect 0x003a 100 100 000 Old_age Always - 0
189 High_Fly_Writes 0x0022 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x001a 077 055 000 Old_age Always - 23 (Min/Max 22/44)
194 Temperature_Celsius 0x0000 023 045 000 Old_age Offline - 23 (0 16 0 0)
195 Hardware_ECC_Recovered 0x0032 070 065 000 Old_age Always - 172448517
197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 0
198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
# smartctl -a /dev/ad6
=== START OF INFORMATION SECTION ===
Device Model: FB080C4080
Serial Number: XXXXX
Firmware Version: XXXXX
User Capacity: 80,026,361,856 bytes
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0
3 Spin_Up_Time 0x0002 098 097 000 Old_age Always - 0
4 Start_Stop_Count 0x0033 100 100 020 Pre-fail Always - 45
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 087 060 030 Pre-fail Always - 602382395
9 Power_On_Hours 0x0032 049 049 000 Old_age Always - 45444
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0033 100 100 020 Pre-fail Always - 46
184 End-to-End_Error 0x0032 100 253 000 Old_age Always - 0
187 Reported_Uncorrect 0x003a 100 100 000 Old_age Always - 0
189 High_Fly_Writes 0x0022 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x001a 077 053 000 Old_age Always - 23 (Min/Max 21/45)
194 Temperature_Celsius 0x0000 023 047 000 Old_age Offline - 23 (0 17 0 0)
195 Hardware_ECC_Recovered 0x0032 073 069 000 Old_age Always - 175463882
197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 0
198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
優秀優秀。45444時間 といえば...1893日も稼働したディスク。このあたりの時代までのHDDはずいぶん長生きしてくれた。
すなわち、5年ちょっと。このサーバ作ってから5年たつんだ...
ML115G1をかって飛びついて作った箱で、M/Bの初期不良を2度踏んだが、それ以外は素直でいいマシンだった。
もう少しがんばってもらおう。HDD80GBじゃつらくてどうしようかと悩んでいて、ファイルサーバを作って、NFSマウントしていたなぁ。今はそれも無くして、別サーバたててリバースプロキシで運用していた。
データセンター侵入イベントをやった後、近くの地下を歩いていたら、大手町フィナンシャルシティにたどり着き、おいしそうなランチがあったので、入ってみた。
OLがたくさん・・・(dkdk)
贅沢をして、ステーキランチ!
味付けは好きだし、ライスもおいしい。
奥の方には、○○のお米、生産者○○とかいた瓶がおいており、食材にはこだわっているようです。
お肉は・・・。うーん。普通すぎました。
出てきたときには冷めちゃってるんですよね。
そこが一番のマイナスポイント。味はいいんですけど。。
お肉ではなく、お野菜、オーガニック料理を食べに、またきたいなぁとおもったところです。
Farm kitchen【洋食】 然 大手町店
東京都千代田区大手町1-9-7 大手町フィナンシャルシティB1
地下鉄丸ノ内線大手町駅 A1番出口 徒歩1分
050-5796-7643
ランチ 月〜金 11:30〜14:30
ディナ 月〜土 17:30〜23:30(L.O.23:00)